- Resistance range: 2.8 to 3.8 Ω
- Response time: ≤ 10 micro second
- Detonator type: Bridge wire
- Safe current: 235 milli Amp.
- Firing current: 600 milli Amp.
Sensitivity 1micro farad capacitor charge to 50 V should cause functioning in ≤ 10 micro sec.
All processes involved in the manufacturing of this detonator are controlled according to ISO: 9001- 2000 accreditation resulting into safe working practices through rigorous risk assessments.